REFRACTORY DRYOUT

It is very much important that proper dryout of refractories should be undertaken as water is the common solvent for mixing of motars, rams, castables , cements used for installation. This water which is hydraulicaly bonded through chemical  interactions, between various refractories after installation needs to be driven out from the lining or else can cause a severe crack by trapping steam in the lining which shall ultimately give way to the entire castable lining. To ensure optimum refractory performance it is imperative that all moisture is removed thoroughly and uniformly during the course of heat-up and prior to the plant being subjected to onstream production.

General description of the procedure of the dry-out of a refractory lining :

For the dry-out of a refractory lining external High velocity burners are used. These external burners are fired with light weight oil/Gas and will be installed in openings like manholes or doors.

One burner unit exists of the mobile burner with the Extended Nozzle, the Combustion fan, regulation flap for the combustion air, the connecting air duct and the regulation unit. The fans are sucking the ambient air and compress it up to max. 60 mbar. This air used for  combustion of the burner.

The burner itself consists of the combustion chamber in which the fuel oil and compressed air/Gas will be mixed with the combustion  air and ignited and the steel part (extended nozzle, manufactured of heat resistant steel) which will lead the flue gases. These extended nozzle could be straight or with an angle and the end so that the flue gas could be led to a desired direction and critical parts close to the burner will not be “touched” directly by the flue gases.

The air duct is used  for the compressed ambient air to the  burner.. The required temperature of the outgoing flue gases will be controlled and achieved by controlling fuel oil by our specialists who are on site continuously.

The flue gas temperature is controlled manually by controlling   oil flow   by valve of the oil train  to achieve required temperature as per the heating schedule.

The maximum temperature reading of all the thermocouple placed  in equipment will considered as target temperature.

Quality Standards :

The all the equipments and Procedure are ISO 9001 : 2000 certified. Safety standred are of international standard and is governed by OHSAS 18001 : 1999.

Refractory Dry out of Pre heater of Cement Plant
Refractory dry out of Kiln Hood
Refractory dry out of Incinerator
BF Stoves heat up in Steel Plant
Dryout at Ammonia Plant
Burner placement in Refinery equipment
Thermal stabilization of Turbine rotor by induction metho
Links
Refractory Dry out of Pre heater of Cement Plant
Refractory dry out of Kiln Hood
Refractory dry out of Incinerato
BF Stoves heat up in Steel Plant
Dryout at Ammonia Plant
Burner placement in Refinery equipment
Thermal stabilization
   
 
 
© Copyright Heat Technologies Pvt. Ltd. 2007
Powered By Barodaweb The E-catalogue Designer